Motor circuit breaker TeSys GV3P32

Model: 003.002.184
Motor circuit breaker TeSys GV3P32
Manufacturer: Schneider Electric
Barcode: 3389119405386

The TeSys GV3P32 circuit breaker is designed for the protection and control of 15kW electric motors (at 400...415Vac 50/60Hz).

The switch combines the following functions:
  • short circuit and overload protection
  • motor on / off control
  • contact position indication
Main characteristics:
  • combination release
  • thermal protection setting range 23...32A
Price by call

Main

rangeTeSys
product nameTeSys GV3
product or component typeCircuit breaker
device short nameGV3P
device applicationMotor
trip unit technologyThermal-magnetic

Complementary

poles description3P
network typeAC
utilisation categoryAC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
network frequency50/60 Hz conforming to IEC 60947-4-1
fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
operating positionAny position
motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control typeRotary knob
[In] rated current32 A
thermal protection adjustment range23…32 A
magnetic tripping current448 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV IEC 60947-2
power dissipation per pole8 W
mechanical durability50000 cycles
electrical durability50000 cycles for AC-3 at 440 V In
maximum operating rate25 cyc/h
rated dutyContinuous conforming to IEC 60947-4-1
tightening torque5 N.m on EverLink BTR screw connectors for cable 25 mm²
8 N.m on EverLink BTR screw connectors for cable 35 mm²
suitability for isolationYes conforming to IEC 60947-1
phase failure sensitivityYes conforming to IEC 60947-4-1
height132 mm
width55 mm
depth136 mm
net weight0.96 kg

Environment

standardsEN/IEC 60947-2
EN/IEC 60947-4-1
CSA C22.2 No 60947-4-1
UL 60947-4-1
product certificationsIECEE CB Scheme
UL
CSA
CCC
EAC
ATEX
BV
LROS (Lloyds register of shipping)
DNV-GL
ABS
protective treatmentTH
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK09
ambient air temperature for operation-20…60 °C
ambient air temperature for storage-40…80 °C
fire resistance960 °C conforming to IEC 60695-2-1
operating altitude3000 m

Dimension

Dimensions of the circuit breaker GV3P series
Electrical clearance X1=40mm for Ue≤ 500V
and X1=50mm for Ue≤ 690V

Scheme

Electrical scheme of the circuit breaker GV3P series

Range of TeSys GV3P series circuit breakers

Model Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range of thermal trips Magnetic tripping current Id ± 20 %
400/415V 500V 690V
P Icu Ics P Icu Ics P Icu Ics
kW kA % kA kA % kW kA % A A
GV3P13 5.5 100 100 7.5 12 50 11 6 50 9...13 182
GV3P18 7.5 100 100 9 12 50 15 6 50 12...18 252
GV3P25 11 100 100 15 12 50 18.5 6 50 17...25 350
GV3P32 15 100 100 18.5 12 50 22 6 50 23...32 448
GV3P40 18.5 50 100 22 12 50 37 6 50 30...40 560
GV3P50 22 50 100 30 12 50 45 6 50 37...50 700
GV3P65 30 50 100 45 12 50 55 6 50 48...65 910
GV3P73 37 50 60 45 12 50 55 6 50 62...73 1120
GV3P80 45 50 60 45 12 50 55 6 50 70...80 1120

Auxiliaries and accessories for GV3P32

background
GV3APN01
 
 
background
GV3APN02
 
 
background
GV3APN04
 
 
background
GVAED101
 
 
background
GVAD0101
 
 
background
GVAN20
 
 
background
GVAN11
 
 
background
GVAE11
 
 
background
GVAU385
 
 
background
GVAS225
 
 
background
GVAD1010
 
 

Similar or replacement products GV3P32