Contactor LC1E40Q5

Model: 004.005.120
Contactor LC1E40Q5
Manufacturer: Schneider Electric
Barcode: 3606480338922
The E-line contactors LC1E40Q5 1NO + 1NC 40A 400V AC3 380V/50Hz offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Price by call

Main

rangeEasyPact
product nameEasyPact TVS
product or component typeContactor
device short nameLC1E
contactor applicationMotor control
Resistive load
utilisation categoryAC-1
AC-3
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: ≤ 690 V AC 50/60 Hz
[Ie] rated operational current40 A (at < 55 °C) at ≤ 440 V AC AC-3 for power circuit
60 A (at < 60 °C) at ≤ 440 V AC AC-1 for power circuit
motor power kW18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 415 V AC 50/60 Hz (AC-3)
22 kW at 440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660...690 V AC 50/60 Hz (AC-3)
control circuit typeAC at 50 Hz
[Uc] control circuit voltage380 V AC 50 Hz
height127 mm
width75 mm
depth114 mm
net weight0.98 kg
colourGrey (RAL 7011)

Complementary

auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
overvoltage categoryIII
Irms rated making capacity400 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity320 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C - 10 s for power circuit
165 A 40 °C - 60 s for power circuit
72 A 40 °C - 600 s for power circuit
associated fuse rating10 A gG at ≤ 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
80 A gG at ≤ 690 V coordination type 1 for power circuit
average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
power dissipation per pole2.4 W AC-3
5.4 W AC-1
control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 Hz (at < 55 °C)
Drop-out: 0.3...0.6 Uc at 50 Hz (at < 55 °C)
operating time20...26 ms on closing
8...12 ms on opening
mechanical durability5000000 cycles
maximum operating rate1200 cyc/h 55 °C
inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)
140 VA 60 Hz cos phi 0.75 (at 20 °C)
hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
heat dissipation6…10 W for control circuit
minimum switching current5 mA for control circuit
minimum switching voltage17 V for control circuit
non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance> 10 MOhm for control circuit
electrical durability350000 cycles AC-1
900000 cycles AC-3
mounting supportPlate
DIN rail
connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Recommended tightening torqueControl circuit: 1.2 N.m
Power circuit: 5 N.m
Max tightening torqueControl circuit: 1.4 N.m
Power circuit: 5.8 N.m

Environment

standardsIEC 60947-4-1
IEC 60947-5-1
IEC 60947-1
product certificationsEAC
CE
IP degree of protectionIP2x conforming to IEC 60529
protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
pollution degree3
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-20…70 °C at Uc
operating altitude3000 m without derating
fire resistance850 °C conforming to IEC 60695-2-1
mechanical robustnessVibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 3 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 11 ms
Shocks contactor closed: 7 Gn for 11 ms

Dimensions and internal circuit

dimensions of contactor LC1E40Q5        Circuit LC1-E40Q5

Auxiliaries and accessories for LC1E40Q5

Similar or replacement products LC1E40Q5