Contactor LC1F115M7

Model: 004.007.016
Contactor LC1F115M7
Manufacturer: Schneider Electric
Barcode: 3389110350876
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Coil LX9FF220 - 220Vac 40...400Hz
Price by call
Main
rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationResistive load
Motor control
utilisation categoryAC-3
AC-1
AC-4
poles description3P
power pole contact composition3 NO
[Ie] rated operational current200 A (at <40 °c) at <=440 v ac-1
115 A (at <55 °c) at <=440 v ac-3< td>
motor power kW55 kW at 380...400 V AC 50/60 Hz (AC-3)
59 kW at 415 V AC 50/60 Hz (AC-3)
59 kW at 440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660...690 V AC 50/60 Hz (AC-3)
30 kW at 220...230 V AC 50/60 Hz (AC-3)
18.5 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage220 V AC 40...400 Hz
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current200 A (at 40 °C)
rated breaking capacity920 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1100 A 40 °C - 10 s
640 A 40 °C - 30 s
520 A 40 °C - 1 min
400 A 40 °C - 3 min
320 A 40 °C - 10 min
associated fuse rating125 A aM at <= 440 V
200 A gG at <= 440 V
average impedance0.37 mOhm - Ith 200 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole15 W AC-1
5 W AC-3
mounting supportPlate
standardsIEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
JIS C8201-4-1
product certificationsRINA
BV
RMRoS
CB
LROS (Lloyds register of shipping)
DNV
UL
CCC
ABS
UKCA
connections - terminalsPower circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 95 mm²
Power circuit: connector 1 cable(s) 95 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bolted connection
tightening torquePower circuit: 10 N.m
Control circuit: 1.2 N.m
control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C)
inrush power in VA770 VA 40...400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA8.1 VA 40...400 Hz cos phi 0.9 (at 20 °C)
heat dissipation5.9…7.2 W
operating time35 ms closing (at Uc)
130 ms opening (at Uc)
mechanical durability10 Mcycles
maximum operating rate2400 cyc/h 55 °C
compatibility codeLC1F
Environment
IP degree of protectionIP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-40…60 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device60…70 °C at Uc
operating altitude3000 m without derating
height162 mm
width163.3 mm
depth171 mm
net weight3.43 kg

Auxiliaries and accessories for LC1F115M7

Similar or replacement products LC1F115M7

background
LC1F115M5
 
 
background
LC1F115P7
 
 
background
SQ0710-0001