Contactor LC1K0601F7 3Р, 6А, 1NC,110V

Model: 004.014.042
  • photo 3
  • photo 4
Contactor LC1K0601F7
Manufacturer: Schneider Electric
Barcode: 3389110429374
TeSys K contactor LC1K0601F7 3P, 6A, 1NC, 110V 50/60H uses for motor protect / isolation
Coil voltage - 110V~ 50/60Hz.
Price by call

Main

rangeTeSys
product or component typeContactor
product nameTeSys K
device short nameLC1K
device applicationControl
contactor applicationMotor control

Complementary

utilisation categoryAC-4
AC-3
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current6 A at <= 440 V AC AC-3 for power circuit
control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-3
2.2 kW at 380...415 V AC 50/60 Hz AC-3
3 kW at 440 V AC 50/60 Hz AC-3
3 kW at 480 V AC 50/60 Hz AC-3
3 kW at 500...600 V AC 50/60 Hz AC-3
3 kW at 660...690 V AC 50/60 Hz AC-3
1.5 kW at 400 V AC 50/60 Hz AC-4
auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
insulation resistance> 10 MOhm for signalling circuit
inrush power in VA30 VA (at 20 °C)
hold-in power consumption in VA4.5 VA (at 20 °C)
heat dissipation1.3 W
control circuit voltage limitsOperational: 0.8...1.15 Uc (at <50 °c)
Drop-out: 0.2...0.75 Uc (at <50 °c)< td>
connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
maximum operating rate3600 cyc/h
auxiliary contacts typetype instantaneous 1 NC
signalling circuit frequency<= 400 Hz
minimum switching current5 mA for signalling circuit
minimum switching voltage17 V for signalling circuit
mounting supportRail
Plate
tightening torque1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
operating time10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
non overlap distance0.5 mm
mechanical durability10 Mcycles
electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V
mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
height58 mm
width45 mm
depth57 mm
net weight0.18 kg

Environment

standardsBS 5424
IEC 60947
NF C 63-110
VDE 0660
product certificationsCSA
UL
UKCA
IP degree of protectionIP2x conforming to VDE 0106
protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
ambient air temperature for storage-50…80 °C
operating altitude2000 m without derating
flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102

Marking of LC1K contactors

LC1K  09 10 M7   
Coil voltage 220V 50/60Hz (see table below)
Auxiliary contacts
10 - 1 normally open contact (NO)
01 - 1 normally close contact (NC)
Rated operational current in category AC-3 (Ue ≤ 440V), A
 6, 9, 12, 16
TeSys K

Auxiliaries and accessories for LC1K0601F7

Similar or replacement products LC1K0601F7