| apparent power | 9.2 kVA at 240 V |
| prospective line Isc | 22 kA |
| continuous output current | 24.2 A at 230 V |
| maximum transient current | 26.6 A for 60 s |
| speed drive output frequency | 0.5…200 Hz |
| nominal switching frequency | 12 kHz |
| switching frequency | 6…16 kHz adjustable 12…16 kHz with derating factor |
| speed range | 1…10 |
| speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| torque accuracy | +/- 15 % |
| transient overtorque | 120 % of nominal motor torque +/- 10 % for 60 s |
| asynchronous motor control profile | Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 2 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 5 points |
| regulation loop | Adjustable PI regulator |
| motor slip compensation | Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load |
| local signalling | 1 LED (red) for DC bus energized |
| output voltage | ≤ power supply voltage |
| isolation | Electrical between power and control |
| type of cable | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 16 mm² / AWG 6 |
| tightening torque | 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) 2.5 N.m, 22 lb.in (L1/R, L2/S, L3/T) |
| supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, < 10 A, protection type: overload and short-circuit protection Internal supply: 24 V DC (21…27 V), < 200 A, protection type: overload and short-circuit protection |
| analogue input number | 2 |
| analogue input type | VIA switch-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0…6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 10 bits |
| sampling duration | 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog |
| response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
| accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C |
| linearity error | VIA: +/- 0.15 % of maximum value for input VIB: +/- 0.15 % of maximum value for input FM: +/- 0.2 % for output |
| analogue output number | 1 |
| analogue output type | FM switch-configurable voltage 0…10 V DC, impedance: 7620 Ohm, resolution 10 bits FM switch-configurable current 0…20 mA, impedance: 970 Ohm, resolution 10 bits |
| discrete output number | 2 |
| discrete output type | Configurable relay logic: (FLA, FLC) NO - 100000 cycles Configurable relay logic: (FLB, FLC) NC - 100000 cycles Configurable relay logic: (RY, RC) NO - 100000 cycles |
| minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
| discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
| discrete input logic | Positive logic (source) (F, R, RES), ≤ 5 V (state 0), >= 11 V (state 1) Negative logic (sink) (F, R, RES), >= 16 V (state 0), ≤ 10 V (state 1) |
| acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 3200 s Automatic based on the load |
| braking to standstill | By DC injection |
| protection type | Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor |
| dielectric strength | 2830 V DC between earth and power terminals 4230 V DC between control and power terminals |
| insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| frequency resolution | Display unit: 0.1 Hz Analog input: 0.024/50 Hz |
| communication port protocol | METASYS N2 APOGEE FLN LonWorks BACnet Modbus |
| connector type | 1 open style 1 RJ45 |
| physical interface | 2-wire RS 485 |
| transmission frame | RTU |
| transmission rate | 9600 bps or 19200 bps |
| data format | 8 bits, 1 stop, odd even or no configurable parity |
| type of polarization | No impedance |
| number of addresses | 1…247 |
| communication service | Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum Write single register (06) Time out setting from 0.1 to 100 s Monitoring inhibitable Read device identification (43) |
| option card | Communication card for LonWorks |
| operating position | Vertical +/- 10 degree |
| width | 180 mm |
| height | 232 mm |
| depth | 170 mm |
| net weight | 6.1 kg |
| power dissipation in W | 249 W |
| air flow | 85 m3/h |
| specific application | HVAC |
| IP degree of protection | IP21 |
| Variable speed drive application selection | Building - HVAC Compressor for scroll Building - HVAC Fan Building - HVAC Pump |
| Motor power range AC-3 | 4…6 kW at 200…240 V 3 phases |
| motor starter type | Variable speed drive |