LRE10 thermal overload relay 4...6 A

Model: 004.030.073
  • photo 3
  • photo 4
LRE10 thermal overload relay 4...6 A
Manufacturer: Schneider Electric
Barcode: 3606480329760
Price by call

Main

rangeEasyPact
product nameEasyPact TVS
product or component typeDifferential thermal overload relay
device short nameLRE
relay applicationMotor protection
phase failure sensitivityTripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
colourGrey RAL 7011

Complementary

product compatibilityLC1E06...38
network typeAC
network frequency50...60 Hz
mounting supportPlate (with specific accessories)
Rail (with specific accessories)
Under contactor
thermal overload classClass 10A conforming to IEC 60947-4-1
signalling functionRelay trip indicator
thermal protection adjustment range4...6 A
tripping threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
mechanical robustnessShocks : 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations : 3 Gn conforming to IEC 60068-2-6
auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal currentSignalling circuit : 5 A
[Ue] rated operational voltage<= 690 V AC
associated fuse ratingPower circuit : 16 A (gG)
Power circuit : 8 A (aM)
Signalling circuit : 5 A (gG)
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV
local signallingTrip indicator
control typeStop : red push-button
Reset : green push-button
temperature compensation-20...60 °C
connections - terminalsScrew clamp terminals (power circuit): 1 flexible cable(s) without cable end of 1.5...6 mm²
Screw clamp terminals (power circuit): 1 flexible cable(s) with cable end of 1...4 mm²
Screw clamp terminals (power circuit): 1 solid cable(s) without cable end of 1...6 mm²
Screw clamp terminals (signalling circuit): 2 flexible cable(s) without cable end of 1...2.5 mm²
Screw clamp terminals (signalling circuit): 2 flexible cable(s) with cable end of 1...2.5 mm²
Screw clamp terminals (signalling circuit): 2 solid cable(s) without cable end of 1...2.5 mm²
tightening torquePower circuit (screw clamp terminals): 1.7 N.m
Signalling circuit (screw clamp terminals): 1.7 N.m
height44.5 mm
width45 mm
depth70 mm
product weight0.13 kg

Environment

standardsIEC 60947-4-1
IEC 60947-5-1
product certificationsGOST
protective treatmentTH conforming to IEC 60068
IP degree of protectionIP20 conforming to IEC 60529
ambient air temperature for operation-20...70 °C with derating
-20...60 °C without derating conforming to IEC 60947-4-1
ambient air temperature for storage-60...80 °C
fire resistance850 °C conforming to IEC 60068-2-1
dielectric strength6 kV at 50 Hz conforming to IEC 60255-5
electromagnetic compatibilitySurge withstand : 6 kV conforming to IEC 60801-5

Auxiliaries and accessories for LRE10

background
LAEB1
 
 

Similar or replacement products LRE10