Contactor LC1F150

Model: 004.007.002
Contactor LC1F150
Manufacturer: Schneider Electric
Barcode: 3389110122244
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Price by call

Main

rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationResistive load
Motor control
utilisation categoryAC-1
AC-4
AC-3
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltage≤ 690 V AC 50/60 Hz
[Ie] rated operational current250 A (at < 40 °C) at ≤ 440 V AC-1
150 A (at < 55 °C) at ≤ 440 V AC-3
motor power kW75 kW at 380...400 V AC 50/60 Hz (AC-3)
80 kW at 415 V AC 50/60 Hz (AC-3)
80 kW at 440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
40 kW at 220...240 V AC 50/60 Hz (AC-3)
100 kW at 660...690 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)

Complementary

[Uc] control circuit voltage24...575 V AC 40...400 Hz with LX1/LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current250 A (at 40 °C)
Irms rated making capacity1500 A conforming to IEC 60947-4-1
rated breaking capacity1200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1200 A 40 °C - 10 s
700 A 40 °C - 30 s
600 A 40 °C - 1 min
450 A 40 °C - 3 min
350 A 40 °C - 10 min
associated fuse rating160 A aM at ≤ 440 V
250 A gG at ≤ 440 V
average impedance0.35 mOhm - Ith 250 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole22 W AC-1
8 W AC-3
control circuit voltage limitsOperational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
heat dissipation5.9…7.2 W
2.2…2.5 W
operating time35 ms closing for with LX1/LX9 coil
130 ms opening for with LX1/LX9 coil
30...40 ms closing for with LX4 coil
30...50 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
mounting supportPlate
standardsIEC 60947-4-1
EN 60947-4-1
IEC 60947-1
EN 60947-1
JIS C8201-4-1
product certificationsRINA
CSA
BV
RMRoS
LROS (Lloyds register of shipping)
DNV
ABS
UL
CB
connections - terminalsPower circuit: lugs-ring terminals 1 cable(s) 120 mm² - busbar cross section: 25 x 3 mm
Power circuit: connector 1 cable(s) 120 mm²
Power circuit: bar 2 cable(s)
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
tightening torquePower circuit: 18 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
mechanical durability10 Mcycles
inrush power in VA690…855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
543…665 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
hold-in power consumption in VA6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
3.94…4.83 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
maximum operating rate2400 cyc/h 55 °C
compatibility codeLC1F

Environment

IP degree of protectionIP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-40…60 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device60…70 °C at Uc
operating altitude3000 m without derating
mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 6 Gn, 5...300 Hz
Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
height170 mm
width163.5 mm
depth171 mm
net weight3.83 kg

Auxiliaries and accessories for LC1F150

Similar or replacement products LC1F150